The SILDIS (Excel) software enables the calculation of a cylindrical silencer with a central rather than peripheral sound-absorbing lining: this is demonstrated by an example (labeled 1.4.5 in the user manual). Noise attenuation is achieved exclusively through the presence of a central sound-absorbing element, what makes namely possible its installation in existing ducts or conduits, as it avoids the complications associated with applying acoustic treatment to the inner walls of the duct itself. For instance, in the case of a chimney where there is a need - a posteriori - to limit the sound power level emitted into the surrounding environment, such a dissipative silencer could quite easily be:

  • craned into place (from the top of the chimney flue, via a vertical downward movement)
  • secured within the flue using a simple lateral guidance system and an overhead support mechanism (suspension)

Regarding the sound-absorbing material, the acoustic structure can be multilayered: it may consist of a core layer of porous medium (e.g. mineral wool or a polyester-based material), a facing layer (such as a non-woven veil or fabric), and a perforated metal sheet to hold the assembly in place.

Wording of the problem (envisaged application relating to the calculation of a cylindrical silencer with a central rather than peripheral sound absorber with software SILDIS)

The objective is to calculate the acoustic and aerolic performance of a cylindrical silencer with a central rather than peripheral sound absorber.

The geometry of the silencer under consideration is shown in Figure 1, the modeling being based - for the envisaged particular case - on the approach developed for the general "C1A" configuration illustrated in Figure 2 (using an appropriate selection of parameters that accounts for the specific absence of a peripheral sound-absorbing lining).

The cross-section of the duct upstream and downstream (before and after the silencer) is equal to the total cross-section of the silencer (total diameter D1A = 13.5", i.e. 342.9 mm [1]), and its length is L = 40", i.e. 1016 mm [3].

Among other possible options, it is assumed (ficticiously) that the silencer features a peripheral lining with a core layer of thickness da = d1 = 1 E-6 m [5], consisting of a locally reacting absorber identified as "BYOb" (resistivity 16 kN·m⁻⁴) [7] in the SILDIS database for porous media. It is modeled as rock wool (DB model) [8] with a perforated facing [9] having a thickness of 1 E-6 m [10] and corresponding to reference "BYOa" (3.5 mm diameter perforations, 0.001% perforation rate). For this fictitious sound-absorbing peripheral lining, thicknesses on the order of microns will not alter the displayed cross-sectional dimensions of the silencer (given a 5-digit precision); furthermore, the inclusion of a perforated sheet with an extremely low perforation rate results in a surface impedance sufficiently high to reflect that of a rigid duct wall, consistent with the actual conditions of the example under consideration.

The silencer is designed for an airflow rate of 1 kg/s [13] at 20°C [14] and a pressure of 101,325 Pa [15]. Propagation loss for lengths L > 1 m is accounted for using the ZER model [16], as is reflection loss [17]. The reference spectrum is pink noise with a sound power level of 130 dB/octave [18]. The total pressure loss is calculated using the 2081 model [19]. The self-noise of the silencer is predicted using the general model 2081e* [20], the ZER thermodynamic correction model [21], and the 2081e spectral correction model [22]. The language to be used is English [23].

With a central absorber (splitter baffle), featuring a core layer with a thickness (radius) of hi = di = d2 = 5" i.e. 127 mm [105]. This core consists of a locally reacting absorber identified as "BYOb" (resistivity 16 kN·m⁻⁴) [107] within the SILDIS database for porous media modeled as rock wool (DB model) [108]. It is covered by a perforated metal sheet [109] with a thickness of 1 E-3 m [110], also corresponding to the "BYOb" specification (perforations with a diameter of 3.5 mm and a perforation rate of 10%).

Cross-sectional dimensions of a cylindrical silencer with a central splitter, without peripheral sound absorber (bar silencer)

Figure 1 Cross-sectional dimensions of a cylindrical silencer with a central splitter, with a central rather than peripheral sound absorber - configuration C1A* - (2hi = 2di = 2d2 = diameter of the central splitter, D1A = 2ha = overall diameter)

 

Figure 1 above (in the specific case of a cylindrical silencer with a central rather than peripheral sound absorber) differs from Figure 2 below (which relates to the general case of a silencer with a circular cross section and an asymmetric sound-absorbing lining) in that in the transverse direction, i.e. perpendicular to the silencer's longitudinal axis no sound propagation is possible, other than that occurring within the central splitter (where da = d1 = 0), what is the basis for the device's acoustic efficiency.

Cross section of a circular/annular silencer

Figure 2 Cross section of a circular/annular silencer - mounting C1A - (da=d1 = peripheral sound absorbing lining thickness, 2ha = inner diameter i.e. connection diameter, 2hi = 2di = 2d2 = pod diameter, D1A = overall diameter)

 

The calculations involved have practical applications, potentially within the scope of engineering or Research and Development (R&D) projects, for the design of various soundproofing hardware (which may utilize other materials for peripheral lining and central splitter - pod -):

  • in the building sector, for Heating, Ventilation, and Air Conditioning (HVAC) systems in residential buildings, public-access facilities, and technical areas 
  • in the industrial sector (inlet and discharge/exhaust systems for fans, motors, and turbomachinery - including compressors and turbines - as well as air-handling systems linked to various processes, including air-cooled condensers and stacks)

In practice, it can be observed that a cylindrical silencer with a central - rather than peripheral - sound absorber (configuration C1A*) is used less frequently than a silencer:

  • with both central and peripheral sound absorbers (mounting C1A)
  • without a central splitter aka pod (mounting C0)

Regardless of the reasons for this, the present publication demonstrates that the challenges involved in predicting the acoustic performance of such a noise-reduction device can be overcome (without any particular extra effort for users of the SILDIS software), and that this latter (deserving to be known), evaluated here in terms of sound transmission loss, is capable of addressing many soundproofing issues, and across a wide frequency range at that.

Naturally, the absence of a sound-absorbing lining along the perimeter increases - for a given overall diameter (D1A) of the silencer - the free cross-sectional area available for fluid flow. This helps limit fluid velocity, which is beneficial for the silencer's performance in terms of:

  • self-generated noise (i.e., noise resulting from the flow)
  • total pressure loss

Furthermore, the simplicity of this noise-mitigation device is generally accompanied by limited production costs.

Improving the acoustic performance (in terms of sound emissions at the outlet) of existing ducts is not the only context in which a silencer with a central rather than peripheral sound absorber might be used.

In the case of a duct with large transverse dimensions (eventually with rectangular silencer section), it may be advantageous to use an array of parallel sound-absorbing elements (aligned with the longitudinal axis of the silencer). The principle for calculating noise attenuation in this scenario remains valid - provided that the dimension D1A of the elementary cell is chosen appropriately - with regard to the propagation of plane sound waves.

Input data (to be entered in Excel worksheets of SILDIS software Module 1)

The input data required for the computation are listed hereafter in reference with the above data (see figures in brackets in the previous §, used as placemarks for explaining the selection below). The input cells are referred to thanks to their Excel’s coordinates (column / line) in the following part extracted from user’s manual.

Worksheet [in COALA] COmputation of Acoustic LAyers

Item Cell for input Foreseen action Input See placemark / comment
Language AF2 For English select E, for French select F E [23]
Temperature (°C) D5 Enter a real number 20 [14]
Pressure (Pa) D6 Enter a real positive number 101325 [15]
Reference (porous medium) I21;J21 Select a reference  (material a list)  BYOb;BYOb [107];[7]
Resistivity (Nsm-4) M22 Enter a real positive number 16000 [107];[7]
General model (porous medium) I27;J27 Select a model (in a list)  DB;DB [108];[8]
Thickness (porous medium) (m) I56;J56 Enter a real positive number 0.254;1E-6 [105]&[110];[5]&[10]
Incorporation of the series perforated protection (0/1) I126;J126 For NO enter 0, for YES enter 1 1;1 [109];[9]
Reference (perforated protection) I71;J71 Select a material (in a list) BYOb;BYOa [111];[11]
Diameter of the holes (m) M72;N72 Entrer a positive real number 3.5E-3;3.5E-3 [111];[11]
Perforation ratio M73;N73 Enter a positive real number 10%;0.001% [111];[11]
Thickness (perforated protection) (m) I127;J127 Enter a real positive number 1E-3;1E-6 [109];[9]
Lw0 (dB ref. 1 pW) C164 to L164 Enter a real positive number for 1/1 octave band sound power level 130 [18]

Worksheet [in COSIL] COmputation of SILencers

Item Cell for input Foreseen action Input See placemark / comment
e(m) BS18 Input a positive real number  0 Pre-filled (0 for mounting C1A)
hi local (m) BV18 Input a positive real number  =BU18 Pre-filled (hi=di=d2)
Mounting C1A to get D1A (m) BS33 Input a positive real number 0.6858 [1]
Half airway (m) D34 Input a positive real number  =BT34 i.e. 0.30389 [6]
Mass flow rate (kg/s) D66 Input a real number  1 [13]
Length L (m) D74 Input a positive real number  1.016 [3]
Model of by-pass correction for L>1m F83 Select a model (in a list) ZER [16]
Model of reflection loss G86 Select a model (in a list) ZER [17]
Model of inlet pressure loss BX96 Select a model (in a list) 2081 [19]
Model of lineic pressure loss BX99 Select a model (in a list) 2081 [19]
Model of outlet pressure loss BX101 Select a model (in a list) 2081 [19]
General model for the flow acoustic power BX106 Select a model (in a list) 2081e* [20]
Model of thermodynamic correction BX107 Select a model (in a list) ZER [21]
Model of spectral correction BX108 Select a model (in a list) 2081e [22]

Calculation results for a cylindrical silencer with a central rather than peripheral sound absorber with Module 1 of software SILDIS

Results: key performance indicators for a cylindrical silencer with a central rather than peripheral sound absorber

Upon completion of the modeling and simulations, and after all calculations, various performance indicators are obtained for the silencer.

Sound power level with silencer 127.0 dB(A), after consideration of regenerated noise which limits sound attenuation

Silencer insertion loss 10.1 dB(A)

Silencer total pressure loss 6 Pa

Results: screenshots of worksheet [in-out CODIS4] (COmputation of DISsipative silencers) of Module 1 of software SILDIS  for a cylindrical silencer with a central rather than peripheral sound absorber

Acoustics

In what follows, performance indicators are linked by the formulas Di’ = Da.L + Dc + Dr ; Lw1 = 10 * log [10^ (0.1 * (Lw0 – Di’)) + 10^ (0.1 * Lw)] ; Di = Lw1 - Lw0

Calculation of the acoustic performance of a cylindrical silencer without peripheral sound-absorber (bar silencer)

Figure 3 Result of the prediction of the acoustic performance of a cylindrical silencer with a central rather than peripheral sound absorber with software SILDIS

 

Aerodynamics/aeraulics

In what follows, performance indicators are linked by the formulas Δpt = ζf * 0.5 * ϱ * (Vf) 2 =  ζp * 0.5 * ϱ * (Vp) 2 with ϱ = density (kg/m3), Vf = front speed (m/s), Vp = passage speed (m/s)

Calculation of the aerolic/aerodynamic performance of a cylindrical silencer without peripheral sound-absorber (bar silencer)

Figure 4 Result of the prediction of the aeraulic/aerodynamic performance of a cylindrical silencer with a central rather than peripheral sound absorber - with software SILDIS

 

Remarks regarding the performance of a cylindrical silencer with a central rather than peripheral sound absorber simulated with Module 1 of software SILDIS

The input data and the outcome displayed in the previous sections are those of the version of Module 1 of the SILDIS software usually marketed; some cells (e.g. model selections for different computation stages) are pre-filled by default with robust selections (that the user can change) for the considered silencer mounting. In order to limit questions from users possibly not familiar with some of the input data to be entered (in relation to what user's manual might be helpful, and dedicated training as well), it is possible to restrict the features of the software package by preventing the modification of some settings for different stages of the computations (to an extend varying on foreseen applications), in oder to make sizings with SILDIS even easier and faster.

The Module 1 of software SILDIS allows cylindrical silencer with a central rather than peripheral sound absorber predicted performance:

  • not exclusively using english language: french can be used too (also for entering input data)
  • possibly in line with the methodology of some engineers associations (when appropriate models are selected in software drop-down menus)
  • possibly comparable with some laboratory measurement standards e.g. NF EN ISO 7235 Acoustics - Laboratory measurement procedures for ducted silencers and air terminal units- Insertion loss, flow noise and total pressure loss (when appropriate models are selected in software drop-down menus)
  • which can be obtained in less than 10 minutes only, including time necessary for data entry in a way similar to the sizing of silencers with a rectangular cross-section, for which a demonstration video is available elsewhere[1] 

The Module 1 of software SILDIS also allows silencer modeling in cases being - sometimes: by far - more demanding than example mentioned above, as some industrial contexts may involve:

  • with more complex service conditions e.g. increased temperature, increased pressure, increase fluid speed in airways, fluid being not dry air
  • with sound absorber being not only rockwool (e.g. glass wool, polyester wool, foam of various kinds), possibly with more sophisticated modeling of acoustical behaviour beyond the consideration of sole flow resistivity e.g. with the consideration of porosity, tortuosity, thermal & viscous charactersitic lengths (in some versions of the software, libraries are available)
  • with more complex acoustic structure for the sound absorbing filling e.g. with perforated sheets (eventually accounting effect of grazing flow in case of high value of Mach number, and effect of high sound levels which are very important in the case of Micro-Perforated Panels - MPP - i.e. with sub-millimeter perforations), with Helmholtz resonators (i.e. with cavities), with different sound absorbing materials for peripheral lining and central splitter (pod)
  • with other geometries e.g. without central pod, with rectangular cross section, with pine-tree shaped splitter baffles; regarding dissipative silencers with a circular cross-section, it is also possible to account geometries with sound absorbing linings in the form of concentric rings

With Module 1 of the SILDIS software, solving the sound propagation equation in the silencer's air passages and in the sound-absorbing lining/pod by means of an analytic method forms the basis for simulating the propagation loss - a fundamental component of acoustic performance -; therefore, none of the limitations often associated with other approaches pose an obstacle. Laboratory tests - allowing parametric regressions - provide the basis for predicting the self noise - due to flow - and the total pressure loss.

Overview of the methodology used for the evaluation of acoustic & aerodynamic performance indicators of cylindrical silencer with a central rather than peripheral sound absorber (configuration C1A*) with Module 1 of software SILDIS

Performance indicator Propagation loss Da.L By-pass correction Dc Reflection loss Dr Flow noise Lw Total pressure loss Δpt
Methodology Analytic Regression based on measurements Analytic (in case of pod) Regression based on measurements Regression based on measurements

Returning to the C1A assembly, i.e. for a circular/annular silencer, as modeled in the context of this calculation example, the applications are numerous:

  • in the building sector, e.g. air conditioning systems, where the ductwork often has a circular cross-section, at least for the most downstream sections: such a noise reduction device is easy to install and provides - at a moderate manufacturing cost - a good compromise between aerodynamic performance - without which the efficiency of a Heating Ventilation Air Conditioning - HVAC - system would be negatively impacted - and acoustic performance - without which there is no acoustic comfort in buildings
  • in industry (both with regard to objectives of decent working conditions and the absence of noise disturbance for residents):
    • in air ducts or similar systems, e.g. exhaust silencers for internal combustion engines, small-capacity gas turbines, soundproofing of chimneys for various processes
    • in pressurized fluid networks of all kinds

Thus, Module 1 of the SILDIS software allows, with a single Excel workbook and a single data entry, the calculation - combining various models - of the aeraulic and acoustic performance of cylindrical silencers without a peripheral sound absorber (mounting C1A*). Besides insertion loss (i.e. transmission loss with infinite input impedance and anechoic termination), the latter also includes a bypass correction (reflecting the fact that the performance of a 4-meter-long silencer is not four times that of a 1-meter-long silencer), in addition to calculating airflow noise (aka regenerated noise).

In fact, the combination of such features makes the SILDIS software package - at the very least - a rare sizing tool, especially when the simulation capabilities it offers come along with numerous other advantages:

  • Module 1 of the SILDIS software avoids the often tedious (complex, delicate, time-consuming, and costly) tasks associated with other silencer performance prediction strategies, thus offering several stengths (due to the approach based on filling in Excel spreadsheet cells with numerical values ​​and/or selecting models from drop-down menus):
    • no specific prerequisites for the user
    • light training, as getting started is easy after a very quick initial support session
    • no necessity to import or create the silencer geometry, due to programmed parametric configuration
    • no necessity to mesh
  • the calculation time is not counted in hours, or even minutes (being the same for small silencer or big silencer)
  • for some versions of the software, the choice of materials can be made (via drop down menu in software) among library embedded in software:
    • for porous media (rock wool, glass wool, basalt wool, polyester wool and ceramic fiber of different densities for wich flow resistivity, porosity, tortuosity, viscous & thermal characteristic lengths are recorded based on laboratory measurements, also with a reference BYO - Bring Your Own - allowing alternatively free enter by user of relevant parameters)
    • for series cloths (glass cloth, fabric for wich airflow resistance and mass density are recorded based on laboratory measurements also with a reference BYO - Bring Your Own - allowing alternatively free enter by user of relevant parameters)
    • for perforated protections (round perforation with various diameters & open area ratios are recorded, also with a reference BYO - Bring Your Own - allowing alternatively free enter by user of relevant parameters)
  • the basic investment is limited to a single (multi-user) license with initial onboarding support for getting started; no additional cost for subsequent years to be foreseen, except advanced support if needed  whatever the reason
  • the license cost is such that even occasional use is sufficient to get shortly return on investment, all the more so when it comes to a software package providing - for example in case of performance of multiple runs - silencer performance predictions that would be more expensive to obtain otherwise (assuming they are then as complete and reliable ?)

Furthermore, can not be compared to SILDIS tools that returns, as a response to a selection query, the performance stored in a database - as some silencer manufacturers have - (or an interpolation of such data), based on measurements (sometimes carried out in time immemorial with poorly documented packing materials or materials that have undergone modifications in terms of the properties induced by their manufacturing methods changes, rarely distinguishing between presence or absence of cloth, fabric or perforated sheet) for a limited number of geometric configurations and which are only valid for air under laboratory conditions (air speed being in general so low that flow direction - with respect to that of the propagation of sound waves - is not accounted).

The Module 1 of software SILDIS (based on Excel) has been made possible by decades of development and validation (in conditions meeting requirement of ISO 9001 relating to quality management systems) in the domain of acoustics (with a specialization in sound propagation and transmission in ducts and multilayer structures) and aerodynamics by a human ressource basing its approcah on the consideration of both theory and practice measurement results (acquired in laboratories, or in-situ). It is a polyvalent, user friendly and reliable tool for sizing dissipative/resonant silencer in all contexts: from easiests cases (ventilation/air conditioning circuits with ambiant thermodynamic conditions) up to most demanding applications in industry e.g. in energy production sector or for test benches (customizations are possible for a tailor-made tool, even for non specialized users).

Programming, sales, training & assistance are available from one company: Isolation Technologie Services aka ITS. Being available with a near-perpetual licence (100 years), Module 1 of software SILDIS is a must-have for anyone aiming to size silencing devices in the context of sound insulation/noise control projects, for engineering studies as well as for Research & Development (e.g. silencer manufacturers or integrators, engineering companies, acoustic consultants & architects offices).

[1] Acoustics and aeraulics - 9 minutes are enough for the complete calculation of a silencer with the SILDIS software: the proof in video

Applications for SILDIS, calculation software for acoustics and aeraulics in the construction sector - in Excel format, for Computer Aided Design (CAD) Features of SILDIS, acoustics simulation software end faq