When one is looking to obtain a noise reduction by the means of a silencer, ITS offers a wide range of noise reduction devices for generator set exhaust for various applications related to acoustic insulation / soundproofing: protection of workers against noise, preservation of acoustic environment, limitation of noise emissions in the energy sector.

ITS offers powerful solutions at a reasonable cost in response to all the needs in the matter of soundproofing (preventive or curative) by the means of equipment (standard or tailor made) for which the quality of design and of execution meets the highest level of requirement in this area for an efficient fight against noise.

Thenoise reduction devices for generator set exhaust offered by ITS allow to reduce the noise due to the discharge of combustion gases from diesel or gas engine and to provide (if required) associated features (such as: spark arrester, pollution control by insertion of a catalytic converter ...) for fixed installations (power plants and sometimes cogeneration units, standby generators: sometimes on platforms at sea, emergency gen-sets) or mobile (ships, locomotives ...).

The noise level close at hand is generally well below the lower values of exposure of workers to noise trigging action and the noise levels in environment are generally well below the limits imposed by regulations in order to avoid sound nuisance.

They are usually made of metallic casing and internal components made of steel (stainless if requested). Depending on needs, the linings of dissipative silencers are with a mineral fiber filling. Some silencers may have an insertion loss Di that can reach 50 dB as a standard with respect to a noise spectrum with low frequencies (a higher performance can be obtained by the means of special constructions).

In many cases, the required acoustic performance can be achieved by implementing a single muffler (either reactive or dissipative, or combined), higher performance being obtained by combining two (or in cases range: 3) mufflers installed in series.

Regardingnoise diminution devices for generator set exhaust proposed by ITS their performance is measured in laboratory according to the current standard:

- standard NF ISO 6798 Reciprocating internal combustion engine - Measurement of emitted airborne noise - Engineering method and survey method

The noise reduction devices for generator set exhaust proposed by ITS can be delivered as a kit ready to assemble with assembly instructions or be installed turnkey.

A guarantee of acoustic performance on site is issued for each installation of noise reduction devices for generator set exhaust.

exhaust silencer for a generator set
exhaust silencer for a generator set

The noise reduction devices for generator set exhaust offered by ITS are robust constructions with quality finishes ensuring a high durability and for which a precise sizing and a tailor made design allow to optimize the aerodynamic performance for an appropriate operation of the power production facilities and a maximal performance.

exhaust silencer for a generator set
exhaust silencers for generator set

 

Download a brochure related to this equipment

Types

FP, FP1 ,FP2 absorptive intake / exhaust gas silencer
FPR, FPD reactiv / absorptive exhaust gas silencer
M21, MA21 reactive exhaust gas silencer
M31, MA31 absorptive exhaust gas silencer
M41, MA41 reactive exhaust gas silencer
M51, MA51 reactive exhaust gas silencer
MRA1, MAA1 reactive / absorptive exhaust gas silencer with or without spark arrester
MRA2, MAA2 reactive / absorptive exhaust gas silencer with or without spark arrester
MRA3, MAA3 reactive / absorptive exhaust gas silencer with or without spark arrester
MSA1, MSA2, MSA3 reactive exhaust gas silencer
BTS2, BTS3, BTS4 box type exhaust silencer


FP/1/2 series


See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

FPR & FPD

See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

M21/MA21 series

See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

M31/MA31 series

See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

M41/MA41 series

See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

M51/MA51 series

See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

MRA1/MAA1 series

See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

MRA2/MAA2 series

See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

MRA3/MAA3 series

See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

MSA1/2/3 series

See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

BTS2/3/4 series 

See the brochure of IMS (ITS is practicing the brokerage for the supply / installation of soundproofing equipment)

See the frequent asked questions related to this equipment

See the frequent asked questions related to this equipment

end faq

As necessary, related equipment can also be provided such as supports, compensators, connecting piping, flanges and counter flanges ...

accessories for exhaust silencers
for generator set
 

 

 

Exhaust silencer for generator set, noise diminution device for generator set exhaust, noise limitation device for generator set exhaust, noise reduction device for generator set exhaust, soundproofing device for generator set: all equipment that one can source thanks to Isolation Technologie Services (ITS).

Such equipments can prevent noise nuisance due to facilities aiming either at electricity generation (e.g. emergency generators) based on diesel engine or on gas engine (e.g. biogas) or at combined electricity and heat production (i.e. cogeneration e.g. with biogas process).

Indeed, such decentralized power generating units often require, given their location (in urban areas e.g. in hospitals where a quiet sound environment is required or in areas with low residual noise e.g. where sound emissions must be limited to meet the regulatory criteria of emergence) special and gigh performing soundproofing equipment.